Indicator phase states IX 300

Indicator phase states IX 300

Indicator phase states IX 300

The IX300 phase status indicator (hereinafter referred to as the device) is designed to indicate the presence of or absence free gas V stream liquids at extraction and transportation oil. Controlled  environments: steam and water mixture, any liquids that are not aggressive towards To steel 12Х18Н10Т and non-destructive sensitive material element.

The device can be used in systems automatic control, regulation and management of technological objects, in other automation devices that receive  constant signals current.Principle actions device based on the indication of the passage of acoustic  impulses  through controlled volume.

Indicator
Converters temperatures A- 2

The device has high resistance to density changes, electrical conductivity, temperature of the controlled liquid,  effects of electromagnetic fields and adhesion to the sensitive element. device has increased strength, For him Not turbulent conditions are critical streams And external vibrations.

device consists of from electronic unit And sensitive element (probe), united V a single structure. On body there is an LED indicator (possible execution device With the presence of an LCD display or percentage indication). The sensitive element consists of from emitter and receiver.

The device can be installed on a pipeline through lubricator.

Main technical characteristics indicator phase states IX300

Parameters controlled environment temperature, °C from minus 40 to + 120
excessive pressure, MPa 6.3
density, kg/m 3 Not is standardized
viscosity, m 2 /s Not is standardized
Range testimony true volumetric gas content 0 – 100%
Range changes weekend signal, scale linear from 4 mA to 20 mA
Size controlled volume, mm 3x3x3
Length submersible parts is being installed By order, mm 50 – 2000
Time averaging data is being installed By order standard 2 With
Resistance loads current exit, Not more, Ohm 150
Voltage nutrition, constant current, IN nominal – 24;

allowed 18- 32;

Voltage, dial-up open collector, IN from 14 to 28
Average term services, years Not less 15
Conditions operation and installation range temperatures surrounding air, °C from minus 55 to plus 75
degree protection corps IP65/P67
marking explosion protection 1 Ex db IIC T6 Gb X
Mode work continuous, round-the-clock

By metrological properties device Not is means measurements, A refers to To product technological control, having precision characteristics.

Structure code order

Code Model
H Converter temperatures range from -50 to +110
T Converter temperatures range from -80 to +300
Code Primary converter
A RTD PT100
Code Scheme connections
2 2- wire
3 3-x wired
4 4-x wired
Code Availability indicator
WITH LCD indicator
B Without LCD indicator
Code Execution By explosion protection
E Explosion protection 1Ex db IIC T6…T1 Gb X
ABOUT Not explosion-proof execution
Code Electrical connection
1 ½” NPT
2 M20x1.5
Code Constructive execution
AND Integral
Code Length dives
U 50..550​ mm It is indicated in numbers necessary depth dives V pipeline
Code Protective sleeve
TO Conical sleeve
C Cylindrical sleeve
Code Accession primary converter To cartridge case
1 ½” NPT
2 ¾” NPT
3 M20x1.5
Code Accession cartridge cases To process
1 M20x1.5
2 M33x2.0
3 ¾” NPT
X specialist. execution, after encodings are indicated necessary connection parameters
Code Day off signal
0 4…20 mA
N Built-in display + 4-20mA+HART
R Built-in display + 4-20mA+RS485
Order example A-2N-A-4- S-E -2-I-150-K-1-2- N