Flow meters mass Coriolis SKX

Flow meters mass Coriolis SKX

Flow meters mass Coriolis SKX

Coriolis mass flow meters (hereinafter referred to as flow meters) are designed to measure mass consumption And masses, temperatures, density, volume consumption And volume liquids V stream.

Typical applications

Flow meters intended For applications V systems​ automatic control, regulation and management streams liquids V various technological​ processes

Peculiarities SKX flow meters

  • high accuracy And repeatability measurements;
  • admissibility availability vibrations pipeline, changes​ temperatures And pressure working environment;
  • Not required rectilinear plots pipeline – yes to And after flow meter;
  • long term services And simplicity maintenance , due to the absence of moving and wearing parts
  • diagnostics malfunctions, emerging V in the process work
  • optical buttons management;
  • adjustment zero on place

Design And principle actions

flow meter consists of from primary flow converter (FC) and electronic converter unit (ECU).

PPR represents by yourself frame, in internal parts of which located two parallel, curved measuring tubes, electromagnetic coil ( coil excitement) And detectors, representing by yourself assembly from coils inductance And permanent magnet, thermistor.

The operating principle of a mass flow meter is based on the use of the Coriolis force that occurs during movement . measurable Wednesday V tube PPR, performing transverse fluctuations.
Under the action of the excitation coil, the PPR tubes perform oscillatory movements V opposite, relatively Friend friend, directions.

integral-1
integral-2

General view

relatively Friend friend, directions. Detectors installed on each side measuring tubes PPR, generate sinusoidal signals forms describing​ movement tubes relatively each other. Liquid, incoming V The primary flow transducer is divided into two equal parts and flows through each measuring tube. As the fluid moves through the measuring tube , a strength Coriolis. In input parts of the tube strength Coriolis directed against the flow tubes, on a day off parts of the tube power Coriolis directed By direction​ movements tubes. Like this in this way, at the entrance parts measuring tubes The Coriolis force prevents the tube from moving, but in the outlet part it promotes it, which leads to To twisting measuring tube. As a result of the tubes twisting, the detectors generate sinusoidal signals with shift phases fluctuations opposite sides of the measuring tubes of the PPR. Difference phases fluctuations opposite​​ sides tubes directly proportional​ mass consumption.

The density of the measured medium is determined by way measurements period vibrations of tubes PPR, which directly proportional – linen density environment.

integral-5
integral-4

EBP provides nutrition PPR And processing​ electrical signals, incoming​ With PPR. EBP carries out registration of results measurements And indication measured​ data on built-in display, generates output signals: current 4-20 mA, frequency-pulse, digital HART, RS485 ( ModBus) RTU) for information transfer V RSU.

Flow meters are being released V two executions :​ integral And separate. Integral​ execution characterized by the installation of an electronic converter unit directly on primary converter consumption. Separate the execution is characterized by remote installation electronic block converter​​ from primary converter consumption at help connecting cable.

Technical characteristics

Name characteristics Meaning
Measurable Wednesday Liquid
Conditional diameter primary converter consumption, mm 3, 6, 15, 25, 40, 50, 80, 100, 150,200
Range measurements mass consumption liquids, t/h from 0.018 to 980
Range measurements density liquids 1 , kg/m 3 from 650 to 1100
Pressure measurable Wednesday, MPa, Not more 25
Range temperatures measurable Wednesday, °C – 70…+250
Weekend signals:
– frequency-pulse, Hz
– current, mA
– digital
from 0 to 10,000 from 4 to 20 mA
HART, RS485 Modbus RTU
Nominal voltage electric nutrition, IN:
– from networks variable current frequency (50/60) Hz
– from external source permanent current
from 85 to 265 from 12 to 36
Consumed power, Tue, Not more 5
Conditions operation:
– temperature surrounding air, °C
– relative humidity air, %, Not more
– atmospheric pressure, kPa
from -40 to +70 95
From 84 to 106.7
Ex -marking flow meters in explosion-proof execution:
– primary converter consumption
– electronic block converter
1Ex ib IIC T6…T2 Gb X 1Ex db [ ib ] IIC T6 Gb X
Degree protection from external influencing impacts
– primary converter consumption
– electronic block converter
IP66 IP66

1) – range indications density liquids from 0 to 3000 kg/m 3 .

Metrological characteristics

Range measurements mass consumption liquids, t/h from 0.018 to 980
Limits permissible relative errors at measurement masses and mass consumption liquids, % ±0.1; ±0.2
Limits permissible relative errors at measurement volume of liquid And volumetric consumption liquids, % ±0.5
Range measurements density liquids, kg/m 3 from 650 to 1100
Limits permissible absolute errors at measurement density of the liquid, kg/m 3 ±1
Range temperatures measurable Wednesday, °C – 40…+155
Limits permissible given errors To range measurements at measurement temperatures liquids, % ± 0.5

Technical characteristics primary converters consumption

Flow meter model Nominal diameter, Du , mm Nominal liquid flow rate , kg/h Maximum liquid flow rate , kg/h Zero stability , kg/h Nominal pressure, MPa
SKX- 003 3 360 540 0.012 4
SKX- 006 6 1200 1800 0.04 10
SKX- 015 15 3000 4500 0.12 25
SKX- 025 25 12000 18,000 0.62 10
SKX- 040 40 30,000 45,000 1.6 10
SKX- 050 50 60000 90000 2.38 10
SKX- 080 80 180,000 270,000 7.05 10
SKX- 100 100 260,000 410000 12 7
SKX- 150 150 480000 620000 50 7
SKX- 200 200 800000 980000 60 7

Overall dimensions dimensions

Flow meter model Connection type A, mm B, mm H, mm W, mm Weight, kg
SKX- 003 DN15 PN40 200±3 243 255 176 10
SKX- 006 DN15 PN40 160±3 235 274 173 3.8
SKX- 015 DN15 PN40 190±3 294 321 185 7
SKX- 025 DN25 PN40 211±3 448 487 216 17.8
SKX- 040 DN40 PN40 261±3 552 589 221 30.2
SKX- 050 DN50 PN40 556±3 506 718 240 34.2
SKX- 080 DN80 PN40 731±3 653 903 289 77.2
SKX- 100 DN100 PN40 755±3 709 1162 345 115.2
SKX- 150 DN150 PN40 1012±3 907 1402 406 214.2
SKX- 200 DN200 PN40 1088±3 907 1468 417 297.2

1) Specified dimensions given For flow meters With flanges EN1092-1. Available various types connections By ASME.

Warranty obligations

Warranty term on flow meters makes up 12 months With dates input V exploitation or 18 months​ With dates supplies, V dependencies from Togo, Which from data periods expires earlier. Average development on refusal – Not less 120,000 h. Average term services – Not less 12 years.

Manufacturer guarantees correspondence flow meter technical requirements at compliance by the consumer conditions transportation, storage And exploitation.

Set supplies

  • Flow meter mass Coriolis
  • Management By

Structure code flow meter For design order

Code Description
1 Brief Name flow meter
SKX
2 Conditional diameter primary converter consumption
003 3 mm
006 6 mm
015 15 mm
025 25 mm
040 40 mm
050 50 mm
080 80 mm
100 100 mm
150 150 mm
200 200 mm
3 Material measuring tubes primary converter consumption
SN Steel stainless steel 316L
CX Alloy Hastelloy C- 276
4 Conditional pressure
1.6 1.6 MPa
4.0 4.0 MPa
6.3 6.3 MPa
10.0 10 MPa
25.0 25 MPa
5 Accession To technological process
XXX Flanged accession, type flange cm. codes And types accession flow meter
R Threaded accession (type required indicate separately)
999 Execution under order (type required indicate separately)
Code Description
6 Range temperatures measurable Wednesday
WITH Standard temperature execution (from minus 70 °C to plus 160 °C)
R Extended temperature execution (from minus 40 °C to plus 200 °C)
B High temperature execution (from minus 40 °C to plus 300 °C)
7 Error
0.1 Error measurements mass consumption liquids ±0.1% And error measurements​​ density liquids 0.001 g/cm 3
0.2 Error measurements mass consumption liquids ±0.2% And error measurements​​ density liquids 0.001 g/cm 3
9 Option execution electronic block converter
AND Integral execution
R Separate execution
10 Voltage nutrition
24 From 12 to 36 IN permanent current
220 From 85 to 265 IN variable current
11 Availability residential complex display
0 Without residential complex display
1 WITH residential complex display
12 Weekend signals
1 4-20 mA + HART, frequency , RS-485 (Modbus) RTU)
2 2 X 4-20 mA, frequency, RS-485 ( Modbus) RTU)
3 4-20 mA, frequency, RS-485 ( Modbus) RTU)
4 Frequency, RS-485 ( Modbus) RTU)
13 Accession under cable input
TO Hole under cable input ½” NPT
M Hole under cable input M20
14 Execution By explosion protection
Ex Explosion-proof execution
Marking explosion protection primary converter 1Ex ib IIC T6…T2 Gb X Marking explosion protection electronic block 1Ex db ( ib ) IIC T6 Gb X
15 Length connecting cable
XXX Specify necessary length cable V meters (max. 150 meters)
Order example SKX -080-SN-4.0-F167-S-0.1-R-24-1-1-M-Ex- 20