flow meter ultrasonic ML

flow meter ultrasonic ML

flow meter ultrasonic ML

The UZR ML is designed for high-precision measurements of volumetric flow rate and volume of liquid in pressure pipelines, as well as For applications V composition reference flow meters installations, verification measuring complexes.

Typical application:

UZR ML have achievements mainly in commercial accounting systems, as well as technological control of various liquids V industries industry.

flow meter ultrasonic ML

Key technical peculiarities

  • High-precision time-lapse ultrasonic method: flow rate determination by signal transit time difference along And against flow
  • Up to 32 ultrasound beams provide complete coverage flow
  • Non-volatile versatility: power Not more 10 W — With opportunity connections UPS
  • Multi-format exits And interfaces
  • Stainless steel or cold-resistant steel body, for any conditions operation
  • Possible installation With abbreviated straight plots

Key advantages

  • High accuracy measurements
  • Explosion-proof execution
  • Reliability And durability
  • Extended diagnostics And functions monitoring
  • Flexibility And versatility
  • Simplicity integration And operation
flow-meter
Principles measurements And technical description

The core of the primary transducer is the active element, which creates four ultrasonic beams. It is made of high-grade PEEK, a polymer known your own mechanical properties And long-term sustainability To hydrocarbons And to the majority chemical products.

Principles measurements And technical description

The operating principle of the ultrasonic detector is based on measuring the transit time of ultrasonic pulses in a moving liquid. By direction movements And against him. The difference between these times proportional average speed fluid movement . For a known cross-sectional area of the pipeline, knowing the distribution speeds V places installations ultrasonic sensors, based on the cross-section of the pipeline, determine the volumetric consumption. At movement liquids through the primary transducer measures the time intervals of ultrasonic passage impulses V acoustic channels.

By results measurements intervals time electronic unit calculates average speed flow measurable Wednesday through transverse section primary converter. Based on the average speed value, the electronic unit calculates the volumetric consumption And volume measurable environment.

UZR consists of from durable flanged corps With two in rows  holes  For  primary  converters.
Acoustic rays, generated primary converters, including analog and digital boards, as well as a power supply. The converter is installed in a sealed explosion-proof body With protection IP67 and provides accurate calculation consumption And transmission data external systems.

Typical scheme installation converters consumption ultrasonic liquids ML

Necessary lengths straight plots pipeline before and after turbine converters consumption are an important condition
For provision accuracy measurements consumption. The optimal length of the straight section allows to stabilize the flow of the medium, minimizes the influence of local resistances and reduces error measurements.
Recommended lengths depend on the flow type and design. himself flow meter.

Principles measurements And technical description

Metric system units

Nominal size, inch Nominal size, mm Number ML models Consumption (m³/h)¹ Min. Consumption (m³/h)¹ Max. Installation length, mm Weight, kg
4 100 ML 04 15 380 406 79
6 150 ML 06 30 800 457 151
8 200 ML 08 60 1400 508 215
10 250 ML 10 90 2200 559 300
12 300 ML 12 130 3200 610 394
14 350 ML 14 160 3800 711 352
16 400 ML 16 200 5000 813 448
18 450 ML 18 250 6200 914 442
20 500 ML 20 350 7800 1016 504
24 600 ML 24 500 11000 1220 721
26 650 ML 26 600 13000 1321 866
28 700 ML 28 700 16,000 1422 1035
30 750 ML 30 700 16,000 1524 1192
32 800 ML 32 700 16,000 1626 1322

Specification

Chapter Parameter Meaning
Surrounding Wednesday Range temperatures surrounding
Wednesday
from -55 °C to +55 °C
Range temperatures working liquids from -55 °C to +120 °C
Temperature storage -50 to +50 °C
Climate protection IP67
Safety Explosion protection 1Ex db mb IIB+H₂ T6…T4 Gb X

Mechanics
Size counter 4″ to 32″ (100 to 800 mm)
Pressure range to 10.0 MPa
Material corps counter Carbon, cold-resistant or corrosion-resistant steel (A106, A333Gr6, 316L, 12X18H10T)
Material flanges Carbon, cold-resistant or corrosion-resistant steel (A105, A350LF2, 316L, 12X18H10T)
Accuracy ±0.10 %; ±0.15 %; ±0.20 %
Maximum consumption — ML – M from 15 to 20,000 m³/h
Technical characteristics Maximum consumption — ML – L from 17 to 20,000 m³/h
Range viscosity — ML – M to 600 sSt , By order to 1500 sSt
Range viscosity — ML – L to 20 sSt , By order to 300 sSt